Implementable Deep Learning for Multi‐sequence Proton MRI Lung Segmentation: A Multi‐center, Multi‐vendor, and Multi‐disease Study

Astley JR., Biancardi AM., Hughes PJC., Marshall H., Collier GJ., Chan H., Saunders LC., Smith LJ., Brook ML., Thompson R., Rowland‐Jones S., Skeoch S., Bianchi SM., Hatton MQ., Rahman NM., Ho L., Brightling CE., Wain LV., Singapuri A., Evans RA., Moss AJ., McCann GP., Neubauer S., Raman B., Wild JM., Tahir BA.

Background Recently, deep learning via convolutional neural networks (CNNs) has largely superseded conventional methods for proton ( 1 H)‐MRI lung segmentation. However, previous deep learning studies have utilized single‐center data and limited acquisition parameters. Purpose Develop a generalizable CNN for lung segmentation in 1 H‐MRI, robust to pathology, acquisition protocol, vendor, and center. Study type Retrospective. Population A total of 809 1 H‐MRI scans from 258 participants with various pulmonary pathologies (median age (range): 57 (6–85); 42% females) and 31 healthy participants (median age (range): 34 (23–76); 34% females) that were split into training (593 scans (74%); 157 participants (55%)), testing (50 scans (6%); 50 participants (17%)) and external validation (164 scans (20%); 82 participants (28%)) sets. Field Strength/Sequence 1.5‐T and 3‐T / 3D spoiled‐gradient recalled and ultrashort echo‐time 1 H‐MRI . Assessment 2D and 3D CNNs, trained on single‐center, multi‐sequence data, and the conventional spatial fuzzy c‐means (SFCM) method were compared to manually delineated expert segmentations. Each method was validated on external data originating from several centers. Dice similarity coefficient (DSC), average boundary Hausdorff distance (Average HD), and relative error (XOR) metrics to assess segmentation performance. Statistical Tests Kruskal–Wallis tests assessed significances of differences between acquisitions in the testing set. Friedman tests with post hoc multiple comparisons assessed differences between the 2D CNN, 3D CNN, and SFCM. Bland–Altman analyses assessed agreement with manually derived lung volumes. A P value of <0.05 was considered statistically significant. Results The 3D CNN significantly outperformed its 2D analog and SFCM, yielding a median (range) DSC of 0.961 (0.880–0.987), Average HD of 1.63 mm (0.65–5.45) and XOR of 0.079 (0.025–0.240) on the testing set and a DSC of 0.973 (0.866–0.987), Average HD of 1.11 mm (0.47–8.13) and XOR of 0.054 (0.026–0.255) on external validation data. Data Conclusion The 3D CNN generated accurate 1 H‐MRI lung segmentations on a heterogenous dataset, demonstrating robustness to disease pathology, sequence, vendor, and center. Evidence Level 4. Technical Efficacy Stage 1.

DOI

10.1002/jmri.28643

Type

Journal article

Publisher

Wiley

Publication Date

2023-10-01T00:00:00+00:00

Volume

58

Pages

1030 - 1044

Total pages

14

Permalink More information Close